What was found
INSPECTION FOUND Z-ANGLE AND FLOOR MOUNTS CORRODED AT AFT SERVICE DOOR THRESHOLD. A NEW Z-ANGLE WAS FABRICATED AND INSTALLED IAW SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND Z-ANGLE AND FLOOR MOUNTS CORRODED AT AFT SERVICE DOOR THRESHOLD. A NEW Z-ANGLE WAS FABRICATED AND INSTALLED IAW SRM 51-30-2.