What was found
INSPECTION FOUND A 8.25 INCH CRACK AT RBL 7.5 AND A 5.25 INCH CRACK AT LBL 6.12 IN BULKHEAD, STA 294.5. THE CRACKED AREAS WERE CUT OUT, DOUBLERS AND FILLERS WERE FABRICATED AND INSTALLED IAW ECRA 5310-03410.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A 8.25 INCH CRACK AT RBL 7.5 AND A 5.25 INCH CRACK AT LBL 6.12 IN BULKHEAD, STA 294.5. THE CRACKED AREAS WERE CUT OUT, DOUBLERS AND FILLERS WERE FABRICATED AND INSTALLED IAW ECRA 5310-03410.