What was found
INSPECTION FOUND A .25 INCH DIAMETER PUNCTURE IN AFT PRESSURE BULKHEAD WEB AT 8:30 POSITION, TWO FEET FROM CENTER. THE DAMAGED AREA WAS REMOVED, A DOUBLER AND FASTENERS WERE FABRICATED AND INSTALLED IAW SRM 53-10-4 AND 51-30-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A .25 INCH DIAMETER PUNCTURE IN AFT PRESSURE BULKHEAD WEB AT 8:30 POSITION, TWO FEET FROM CENTER. THE DAMAGED AREA WAS REMOVED, A DOUBLER AND FASTENERS WERE FABRICATED AND INSTALLED IAW SRM 53-10-4 AND 51-30-0.