What was found
INSPECTION FOUND FLOOR ATTACH ANGLE CORRODED FROM BS 290 TO 360, LBL 65. REMOVED CHORD AND INSTALLED NEW CHORD IAW SRM 51-30-2. A DOUBLER AND FILLER FLOOR WEB WAS FABRICATED AND INSTALLED IAW SRM 51-40-2 AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOOR ATTACH ANGLE CORRODED FROM BS 290 TO 360, LBL 65. REMOVED CHORD AND INSTALLED NEW CHORD IAW SRM 51-30-2. A DOUBLER AND FILLER FLOOR WEB WAS FABRICATED AND INSTALLED IAW SRM 51-40-2 AND 51-30-2.