What was found
INSPECTION FOUND A SIX INCH CRACK IN BULKHEAD AT STA 178, WL 208, RBL 18. ALSO, A SIX INCH CRACK WAS FOUND IN BULKHEAD AT STA 178, WL 208, LBL 16. THE CRACKED AREAS WERE REMOVED IAW SRM 53-10-11. FILLER AND DOUBLER WERE FABRICATED AND INSTALLED IAW SRM 53-10-11 AND 51-30-2.