What was found
INSPECTION FOUND A 1 INCH CRACK IN FLOOR SUPPORT L-ANGLE AT CENTER CARGO FORWARD BULKHEAD FS 1521, RBL 19. THE CRACK WAS STOP DRILLED, AN L-ANGLE AND DOUBLERS WERE FABRICATED AND INSTALLED IAW SRM 53-00-01, FIGURE 2 AND 51-31-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A 1 INCH CRACK IN FLOOR SUPPORT L-ANGLE AT CENTER CARGO FORWARD BULKHEAD FS 1521, RBL 19. THE CRACK WAS STOP DRILLED, AN L-ANGLE AND DOUBLERS WERE FABRICATED AND INSTALLED IAW SRM 53-00-01, FIGURE 2 AND 51-31-01.