What was found
INSPECTION FOUND FLOOR SUPPORT CORRODED AT STA 879 AND 899, Y= -44. CHANNEL FLOOR SUPPORT ANGLES AND BOSSES WERE FABRICATED AND INSTALLED IAW SRM 51-31-01, 51-21-01 AND 53-70-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOOR SUPPORT CORRODED AT STA 879 AND 899, Y= -44. CHANNEL FLOOR SUPPORT ANGLES AND BOSSES WERE FABRICATED AND INSTALLED IAW SRM 51-31-01, 51-21-01 AND 53-70-00.