What was found
INSPECTION FOUND THREE CRACKS UP TO .30 INCH LONG IN FLOORBOARD SUPPORT AT STA 1943, X - 11 TO 16. A NEW FLOOR SUPPORT WAS FABRICATED AND INSTALLED IAW SRM 51-21-01 AND 51-31-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND THREE CRACKS UP TO .30 INCH LONG IN FLOORBOARD SUPPORT AT STA 1943, X - 11 TO 16. A NEW FLOOR SUPPORT WAS FABRICATED AND INSTALLED IAW SRM 51-21-01 AND 51-31-01.