What was found
INSPECTION FOUND SUBFLOOR CORRODED AT STA 852, LBL 44. THE CORRODED AREA WAS REMOVED AND A REPAIR WEB WAS INSTALLED IAW SRM 53-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND SUBFLOOR CORRODED AT STA 852, LBL 44. THE CORRODED AREA WAS REMOVED AND A REPAIR WEB WAS INSTALLED IAW SRM 53-01.