What was found
FLOOR SUPPORT BEAM UPPER CHORD HAS CORROSION BETWEEN BL 48 RT AND BL 58 RT AT STATION 380. CUT OUT DAMAGED AREA AND FABRICATED REPAIR IN ACCORDANCE WITH SRM 53-10-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT BEAM UPPER CHORD HAS CORROSION BETWEEN BL 48 RT AND BL 58 RT AT STATION 380. CUT OUT DAMAGED AREA AND FABRICATED REPAIR IN ACCORDANCE WITH SRM 53-10-8.