What was found
INSPECTION FOUND A 2 INCH CRACK IN INTERCOSTAL IN FORWARD CARGO PIT AT STA 500A TO 500B, STRINGER 26R. THE CRACK WAS STOP DRILLED, A DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 51-00-00, FIGURE 23, 51-40-2, AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A 2 INCH CRACK IN INTERCOSTAL IN FORWARD CARGO PIT AT STA 500A TO 500B, STRINGER 26R. THE CRACK WAS STOP DRILLED, A DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 51-00-00, FIGURE 23, 51-40-2, AND 51-30-2.