What was found
INSPECTION FOUND AFT CABIN CLOSET TO FLOOR ATTACH CHANNEL CORRODED AT STA 1016 TO AFT PRESSURE BULKHEAD, RBL 2. THE CORRODED AREA WAS REMOVED, A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 51-30-2 AND 51-10-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND AFT CABIN CLOSET TO FLOOR ATTACH CHANNEL CORRODED AT STA 1016 TO AFT PRESSURE BULKHEAD, RBL 2. THE CORRODED AREA WAS REMOVED, A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 51-30-2 AND 51-10-2.