What was found
INSPECTION FOUND A 1.5 INCH CRACK IN FLOOR WEB AT STA 986 TO 995, RBL 43. THE CRACKED AREA WAS REMOVED IAW SRM 51-40-2, A REPAIR DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 51-40-3, 51-30-3, AND 51-10-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A 1.5 INCH CRACK IN FLOOR WEB AT STA 986 TO 995, RBL 43. THE CRACKED AREA WAS REMOVED IAW SRM 51-40-2, A REPAIR DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 51-40-3, 51-30-3, AND 51-10-3.