What was found
INSPECTION FOUND L-ANGLE CORRODED AT STA 267 TO 277, LBL 12 TO RBL 12. A REPLACEMENT ANGLE WAS FABRICATED AND INSTALLED IAW SRM 53-10-2 AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND L-ANGLE CORRODED AT STA 267 TO 277, LBL 12 TO RBL 12. A REPLACEMENT ANGLE WAS FABRICATED AND INSTALLED IAW SRM 53-10-2 AND 51-30-2.