What was found
INSPECTION FOUND A 2 INCH CRACK IN FORWARD FRAME OF R-1 DOOR AT STA 294, STRINGER 17R. THE CRACKED AREA WAS CUT OUT, A REPAIR WAS INSTALLED IAW SRM 51-40-3, 51-30-2, AND 51-10-6.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A 2 INCH CRACK IN FORWARD FRAME OF R-1 DOOR AT STA 294, STRINGER 17R. THE CRACKED AREA WAS CUT OUT, A REPAIR WAS INSTALLED IAW SRM 51-40-3, 51-30-2, AND 51-10-6.