What was found
INSPECTION FOUND FLOOR SUPPORT CORRODED IN CENTER CARGO COMPARTMENT AT STA 1781, RBL 45 TO LBL 20. AN ANGLE WAS FABRICATED AND INSTALLED IAW SRM 53-15-01, FIGURE 14A, ITEM 22.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOOR SUPPORT CORRODED IN CENTER CARGO COMPARTMENT AT STA 1781, RBL 45 TO LBL 20. AN ANGLE WAS FABRICATED AND INSTALLED IAW SRM 53-15-01, FIGURE 14A, ITEM 22.