What was found
INSPECTION FOUND STRINGER 29L CORRODED AT STA 1012. THE CORRODED AREA WAS CUT OUT, A SPLICE AND STRINGER WERE FABRICATED AND INSTALLED IAW SRM 53-10-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND STRINGER 29L CORRODED AT STA 1012. THE CORRODED AREA WAS CUT OUT, A SPLICE AND STRINGER WERE FABRICATED AND INSTALLED IAW SRM 53-10-3.