What was found
INSPECTION FOUND FLOOR SUPPORT CORRODED JUST INSIDE DOORWAY WEB AT FS 1155 TO 1212. THE FLOOR SUPPORT WAS REMOVED AND A REPLACEMENT SUPPORT WAS FABRICATED AND INSTALLED IAW SRM 51-30-2 AND 51-10-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOOR SUPPORT CORRODED JUST INSIDE DOORWAY WEB AT FS 1155 TO 1212. THE FLOOR SUPPORT WAS REMOVED AND A REPLACEMENT SUPPORT WAS FABRICATED AND INSTALLED IAW SRM 51-30-2 AND 51-10-3.