What was found
INSPECTION FOUND FLOORBEAM WEB CORRODED AT STA 1338, LONGERON 19R. THE WEB WAS REPAIRED IAW ECRA 5310-03513 AND SRM 53-01, FIGURE 4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOORBEAM WEB CORRODED AT STA 1338, LONGERON 19R. THE WEB WAS REPAIRED IAW ECRA 5310-03513 AND SRM 53-01, FIGURE 4.