What was found
INSPECTION FOUND CORROSION ON UPPER SURFACE OF FLOORBEAM AT STA 344, LBL 30. THE CORRODED SECTION WAS CUT OUT. A BEAM REPAIR WAS FABRICATED AND INSTALLED IAW SRM 53-10-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND CORROSION ON UPPER SURFACE OF FLOORBEAM AT STA 344, LBL 30. THE CORRODED SECTION WAS CUT OUT. A BEAM REPAIR WAS FABRICATED AND INSTALLED IAW SRM 53-10-8.