What was found
INSPECTION FOUND FLOORBEAM CORRODED AT STA 1110 FROM BL 0 TO RT WALL. THE CORRODED AREA WAS CUT OUT, A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 53-10-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOORBEAM CORRODED AT STA 1110 FROM BL 0 TO RT WALL. THE CORRODED AREA WAS CUT OUT, A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 53-10-8.