What was found
INSPECTION FOUND LONGERON END FITTING CORRODED AT STA 1156, LONGERON 47L. THE FITTING WAS REMOVED AND A NEW FITTING WAS FABRICATED AND INSTALLED IAW SRM 51-21-01, 51-31-01, AND 51-33-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND LONGERON END FITTING CORRODED AT STA 1156, LONGERON 47L. THE FITTING WAS REMOVED AND A NEW FITTING WAS FABRICATED AND INSTALLED IAW SRM 51-21-01, 51-31-01, AND 51-33-01.