What was found
INSPECTION FOUND FLOORBEAM UPPER CHORD CORRODED AT STA 312, LBL 8 TO RBL 24. THE CORRODED AREA WAS REMOVED, A NEW SECTION OF BEAM WAS FABRICATED AND INSTALLED IAW SRM 53-10-51, FIGURE 205.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOORBEAM UPPER CHORD CORRODED AT STA 312, LBL 8 TO RBL 24. THE CORRODED AREA WAS REMOVED, A NEW SECTION OF BEAM WAS FABRICATED AND INSTALLED IAW SRM 53-10-51, FIGURE 205.