What was found
INSPECTION FOUND CORROSION IN TWO SPOTS ON INTERIOR SURFACE OF LT WING OUTBOARD HINGE PANEL 536DL. THE CORRODED AREAS WERE REMOVED IAW SRM 51-43-01. DOUBLERS WERE FABRICATED AND INSTALLED IAW SRM 57-32-01 AND 51-21-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND CORROSION IN TWO SPOTS ON INTERIOR SURFACE OF LT WING OUTBOARD HINGE PANEL 536DL. THE CORRODED AREAS WERE REMOVED IAW SRM 51-43-01. DOUBLERS WERE FABRICATED AND INSTALLED IAW SRM 57-32-01 AND 51-21-01.