What was found
AFT SPAR LEFT SIDE AFT TANG CRACKED (.250) FROM BUTE DOOR ATTACH HOLE APPROXIMATELY 5 OUTBOARD OF STATION 164. CUT OUT 2 CRACK AREA. FABRICATED AND INSTALLED REPAIR IN ACCORDANCE WITH EC/RA 5710-01844 AND DRAWING J060271-503.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT SPAR LEFT SIDE AFT TANG CRACKED (.250) FROM BUTE DOOR ATTACH HOLE APPROXIMATELY 5 OUTBOARD OF STATION 164. CUT OUT 2 CRACK AREA. FABRICATED AND INSTALLED REPAIR IN ACCORDANCE WITH EC/RA 5710-01844 AND DRAWING J060271-503.