What was found
INSPECTION FOUND A 2 INCH CRACK IN INTERCOSTAL BEAM AT STA 848, BL 0, AT BOTH LT AND RT SIDES. THE CRACKED AREA WAS CUT OUT, FILLERS AND DOUBLERS WERE FABRICATED AND INSTALLED IAW SRM 51-40-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A 2 INCH CRACK IN INTERCOSTAL BEAM AT STA 848, BL 0, AT BOTH LT AND RT SIDES. THE CRACKED AREA WAS CUT OUT, FILLERS AND DOUBLERS WERE FABRICATED AND INSTALLED IAW SRM 51-40-3.