What was found
INSPECTION FOUND FLOORBEAM SUPPORT ANGLE CORRODED AT STA 1845, RBL 25. THE SUPPORT WAS REMOVED AND A REPLACEMENT SUPPORT WAS FABRICATED AND INSTALLED IAW SRM 51-31-01, 53-16-0, AND 51-10-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOORBEAM SUPPORT ANGLE CORRODED AT STA 1845, RBL 25. THE SUPPORT WAS REMOVED AND A REPLACEMENT SUPPORT WAS FABRICATED AND INSTALLED IAW SRM 51-31-01, 53-16-0, AND 51-10-01.