Service difficulty report · Sensor · Doug DC932

Difficulty date
February 17, 1998
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N19504
Make and model
Doug DC932
Aircraft serial
47638
Part
Sensor
Part number
10200074
Condition
Inoperative
Location
Rt De-Ice Syst
Stage of operation
TO
Nature of condition
B, J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

THE RT AIR CONDITIONING SUPPLY TEMP HIGH LIGHT ILLUMINATED AFTER TAKEOFF WITH SMOKE IN THE CABIN. THE AIRFOIL ICE PROTECTION WAS ON. THE PACK WAS TURNED OFF AND THE SMOKE DISSIPATED. THE RT ICE PROTECTION HIGH TEMP SENSOR WAS REMOVED AND REPLACED IAW MM 30-10-6. THE ENGINES WERE RUN WITH PACKS OPERATING AND NO DEFECTS WERE NOTED.