What was found
INSPECTION FOUND SEVEN SMALL DENTS 18 INCHES AFT OF LOWER AFT CORNER OF L-1 DOOR NEAR CUSP LINE. AN EDDY CURRENT INSPECTION FOUND NO CRACKS. THE DENTS WERE PLACED ON DIP PER SRM 53-04, PAGE 212, CONDITION 2. THE DIP SPECIFIED INSPECTION EVERY 3500 LANDINGS AND REPAIR BY 15,000 LANDINGS.