What was found
CANTED FRAME HAS IMPROPER STOP DRILL HOLES AT END OF CRACKS WITH CRACK GOING BEYOND DRILLED HOLES AT STA 1446 IN 8 PLACES (10 TOTAL FOR ALL CRACKS). REPLACD BELTFRAME AT STATION 1446 FROM LONG 10 LT TO 10 RT PER SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CANTED FRAME HAS IMPROPER STOP DRILL HOLES AT END OF CRACKS WITH CRACK GOING BEYOND DRILLED HOLES AT STA 1446 IN 8 PLACES (10 TOTAL FOR ALL CRACKS). REPLACD BELTFRAME AT STATION 1446 FROM LONG 10 LT TO 10 RT PER SRM 51-30-2.