What was found
CABIN FLOORBEAM ATTACH ANGLE CRACKED STA 520 BL 0.0. REMOVED CRACKED ATTACH ANGLE. FABRICATED, TREATED, PRIMED AND INSTALLED NEW ANGLE PER SRM 51-40-3, 51-10-2 AND MM 51-20-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOORBEAM ATTACH ANGLE CRACKED STA 520 BL 0.0. REMOVED CRACKED ATTACH ANGLE. FABRICATED, TREATED, PRIMED AND INSTALLED NEW ANGLE PER SRM 51-40-3, 51-10-2 AND MM 51-20-0.