What was found
FWD SERVICE DOOR JAMB INTERIOR STRUCTURE BETWEEN STA 160 - 170 AND BETWEEN LONGERONS 12 R AND 13 R IS CRACKED (2). ROUTED OUT CRACKED AREA. FABRICATED, PRIMED AND INSTALLED NEW ANGLE PER SRM 51-10-3 AND 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD SERVICE DOOR JAMB INTERIOR STRUCTURE BETWEEN STA 160 - 170 AND BETWEEN LONGERONS 12 R AND 13 R IS CRACKED (2). ROUTED OUT CRACKED AREA. FABRICATED, PRIMED AND INSTALLED NEW ANGLE PER SRM 51-10-3 AND 51-30-5.