What was found
INSPECTION FOUND LT FLOORBEAM AT BS 996, LBL 18 CORRODED. AN UPPER CAP WAS FABRICATED AND INSTALLED IAW SRM 51-30-0 AND 51-10-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND LT FLOORBEAM AT BS 996, LBL 18 CORRODED. AN UPPER CAP WAS FABRICATED AND INSTALLED IAW SRM 51-30-0 AND 51-10-1.