INSPECTION FOUND A 1 INCH CRACK IN FLOOR SUPPORT IN FORWARD CARGO COMPARTMENT AT STA 236, STRINGER 27R. THE CRACK WAS STOP DRILLED IAW ECRA 5320-01263. AN ANGLE WAS FABRICATED AND INSTALLED IAW ECRA 5320-01263.