What was found
INSPECTION FOUND FLOORBEAM CORROSION AT STA 980, LBL 34, STA 996, LBL 27, AND STA 965, LBL 16. L-ANGLES AND FILLERS WERE FABRICATED AND INSTALLED AT EACH LOCATION IAW SRM 53-05, FIGURE 20A AND 51-10-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOORBEAM CORROSION AT STA 980, LBL 34, STA 996, LBL 27, AND STA 965, LBL 16. L-ANGLES AND FILLERS WERE FABRICATED AND INSTALLED AT EACH LOCATION IAW SRM 53-05, FIGURE 20A AND 51-10-3.