What was found
INSPECTION FOUND A .75 INCH CRACK THROUGH FASTENER HOLE OF SKIN AT LT SIDE OF VERTICAL STABILIZER AROUND ACCESS PANEL 9523 ABOVE BS 1215. THE CRACK WAS STOP DRILLED, A DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 51-10-0, 55-30-3, 51-10-2, 51-30-2, AND 51-00-00.