What was found
INSPECTION FOUND A .5 INCH CRACK IN INTERCOSTAL WEB TOP ANGLE AT FORWARD SCREW HOLE BETWEEN FLOORBEAMS AT BS 970-990, BL 0. THE TOP ANGLE WAS REMOVED. A NEW ANGLE WAS FABRICATED AND INSTALLED IAW SRM 51-10-6 AND 51-40-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A .5 INCH CRACK IN INTERCOSTAL WEB TOP ANGLE AT FORWARD SCREW HOLE BETWEEN FLOORBEAMS AT BS 970-990, BL 0. THE TOP ANGLE WAS REMOVED. A NEW ANGLE WAS FABRICATED AND INSTALLED IAW SRM 51-10-6 AND 51-40-3.