What was found
INSPECTION FOUND RT AFT LAV FIXED FLOOR CORRODED INCLUDING AROUND DUMP CHUTE AT BS 1129-1176, RBL 25-63. THE CORROSION WAS REMOVED. A DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 51-30-2, 51-10-2, 51-40-5, AND 51-10-6.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND RT AFT LAV FIXED FLOOR CORRODED INCLUDING AROUND DUMP CHUTE AT BS 1129-1176, RBL 25-63. THE CORROSION WAS REMOVED. A DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 51-30-2, 51-10-2, 51-40-5, AND 51-10-6.