What was found
INSPECTION FOUND A HOLE IN FORWARD PIT FLOOR PANEL AT STA 640-720. THE DAMAGED AREA WAS CUT OUT. TWO DOUBLERS AND REPAIR FILLER WERE FABRICATED AND INSTALLED IAW SRM 53-10-7, 51-10-2, 51-30-2, AND MM 51-20-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A HOLE IN FORWARD PIT FLOOR PANEL AT STA 640-720. THE DAMAGED AREA WAS CUT OUT. TWO DOUBLERS AND REPAIR FILLER WERE FABRICATED AND INSTALLED IAW SRM 53-10-7, 51-10-2, 51-30-2, AND MM 51-20-11.