What was found
INSPECTION FOUND A 1 INCH CRACK IN FRAME AT STA 804.5, STRINGER 14L. A 1.5 INCH CRACK WAS FOUND IN FRAME AT STA 804.5, STRINGER 14R. AN ANGLE WAS INSTALLED AT EACH LOCATION IAW SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A 1 INCH CRACK IN FRAME AT STA 804.5, STRINGER 14L. A 1.5 INCH CRACK WAS FOUND IN FRAME AT STA 804.5, STRINGER 14R. AN ANGLE WAS INSTALLED AT EACH LOCATION IAW SRM 51-30-2.