What was found
INSPECTION FOUND A .5 INCH CRACK IN BOTH INBOARD AND OUTBOARD RIBS OF NR 4 SLAT AT ACTUATOR ROD END ATTACH POINT. THE ACCESS PANEL ON NR 4 SLAT WAS REMOVED IAW SRM 51-30-2. THE CRACKED RIBS WERE REMOVED IAW SRM 51-30-2. NEW RIBS WERE INSTALLED IAW SRM 51-30-4 AND 51-30-2. THE ANTI-ICE DUCTS AND ACCESS PANEL WERE REINSTALLED IAW MM 30-11-81 AND SRM 51-30-2.