What was found
INSPECTION FOUND A .5 INCH CRACK AT TOP FLANGE OF INTERCOSTAL THREE INCHES AFT OF FLOOR FRAME FS 970, BL 0. THE TOP FLANGE WAS REMOVED AND A NEW SECTION WAS INSTALLED IAW SRM 51-30-2 AND 51-20-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A .5 INCH CRACK AT TOP FLANGE OF INTERCOSTAL THREE INCHES AFT OF FLOOR FRAME FS 970, BL 0. THE TOP FLANGE WAS REMOVED AND A NEW SECTION WAS INSTALLED IAW SRM 51-30-2 AND 51-20-1.