What was found
RT WING NR 5 FLAP FWD INBOARD FAIRING BRACKET CRACKED IN RADIUS .25 INCH LONG. FABRICATED ANGLE FROM 7075 T6 .063. LOCATED, DRILLED, DEBURRED, TREATED, PRIMED, AND INSTALLED PER SRM 51-40-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT WING NR 5 FLAP FWD INBOARD FAIRING BRACKET CRACKED IN RADIUS .25 INCH LONG. FABRICATED ANGLE FROM 7075 T6 .063. LOCATED, DRILLED, DEBURRED, TREATED, PRIMED, AND INSTALLED PER SRM 51-40-3.