What was found
NR 4 FLAP TRACK FAIRING AFT INBOARD ANGLE IS CRACKED .5 LONG. STOP DRILLED CRACK ON NR 4 FLAP TRACK FAIRING. FABRICATED REPAIR FROM 7075 T6 .050. LOCATED, DRILLED, DEBURRED, ALODINED, PRIMED PER SRM 51-40-3, 51-10-2, MM 51-20-12 AND INSTALLED PER SRM 51-30-2.