As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FORWARD ZONE A EMERGENCY LIGHTS INOP. DOOR 1L EXIT SIGN DISASSEMBLED AND WIRING FROM TERMINAL 1 FOUND SHORTED TO TERMINAL 2. DOOR EXIT SIGN WIRING RE-MADE. EMERGENCY LIGHT BATTERY CHARGER FITTED TO ZONE A. ALL DISTRIBUTED WIRING RE-MADE AND SYSTEM CHECKED PER MM 33-51-01 AND 33-55-00.