What was found
INSPECTION FOUND A .5 INCH CRACK IN FLOOR LEVEL RIB AT RT SIDE OF STA 344. A STRAP WAS INSTALLED IAW SRM 51-10-2 AND 53-10-8 FIGURE 6.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A .5 INCH CRACK IN FLOOR LEVEL RIB AT RT SIDE OF STA 344. A STRAP WAS INSTALLED IAW SRM 51-10-2 AND 53-10-8 FIGURE 6.