What was found
INSPECTION FOUND RT AFT LAV SUBFLOOR CORRODED. THE CORRODED AREA WAS REMOVED AND A REPAIR WAS INSTALLED IAW SRM 51-30-2 PAGE 4, 51-10-6 PAGE 2 AND 51-10-2 PAGE 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND RT AFT LAV SUBFLOOR CORRODED. THE CORRODED AREA WAS REMOVED AND A REPAIR WAS INSTALLED IAW SRM 51-30-2 PAGE 4, 51-10-6 PAGE 2 AND 51-10-2 PAGE 1.