What was found
INSPECTION FOUND GALLEY FLOOR SUPPORT CORRODED AT STA 791, RBL 50 TO 70. THE FLOOR SUPPORT WAS REMOVED AND A NEW FLOOR SUPPORT WAS INSTALLED IAW SRM 51-31-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND GALLEY FLOOR SUPPORT CORRODED AT STA 791, RBL 50 TO 70. THE FLOOR SUPPORT WAS REMOVED AND A NEW FLOOR SUPPORT WAS INSTALLED IAW SRM 51-31-01.