What was found
INSPECTION FOUND FLOOR SUPPORT CORRODED AT STA 1902 TO 1921, RBL 26. THE FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-31-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOOR SUPPORT CORRODED AT STA 1902 TO 1921, RBL 26. THE FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-31-01.