What was found
INSPECTION FOUND FOUR .5 INCH CRACKS IN CANTED FRAME AT STA 1105, LONGERON 3L, 4L, 5L, AND 3R. THE FRAME WAS REPLACED WITH A NEW CANTED FRAME IAW SRM 51-30-1, 51-30-2, AND 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FOUR .5 INCH CRACKS IN CANTED FRAME AT STA 1105, LONGERON 3L, 4L, 5L, AND 3R. THE FRAME WAS REPLACED WITH A NEW CANTED FRAME IAW SRM 51-30-1, 51-30-2, AND 51-30-5.